6Setup Procedures
6-25
NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is
the HEX value of the character). Since a / is the start of any HEX value, you
must type "//" to output a slash. PC function keys may be defined as /F0
through F9. Function key F10 is defined as /F0. Refer to M3000 User's
Guide, Appendix K and L for Special Character values.
EOT Delay
The end of transmit text transmit delay defines the amount of time delay that is inserted between
each character of the EOT Text during file transmission. This is used to slow down the data output
rate so that the M3000 does not generate a data overrun on the host computer during transmission,
especially when transmitting data by keyboard wedge. The time delay is in tenths of a second (0.0
- 9.9 seconds). Most systems do not need an EOT Delay.
Field Requirements:
EOT Delay is required
1 to 2 characters allowed
Numeric data accepted (0 to 99) Default is 0
Other Setup
Timeout
Sets the amount of time the M3000 remains ON after the last activity on the unit. Timeout is
disabled while operating in NON PORTABLE modes. Default Timeout is 5 minutes.
1-99 Minutes or OFF.
Password
ON The SETUP mode password must be entered to access the SETUP mode. The SETUP
password is "OK". This is a fixed password and cannot be changed.
OFF* Entry of the SETUP mode password is not required to access the SETUP mode.
Auto Input (Automatic Input)
When you select Automatic Input the M3000 automatically loads a program and data file any time
FUNC INPUT is selected.
Automatic Input uses the first program found in RAM. If no data file exists for the program, the
M3000 creates a file named- FILE #1. If a data file, or multiple data files exist for the active
program, the M3000 uses the first file created for that program.
ON Enables Auto Input.
OFF* Disables Auto Input.
Auto Save
ON Automatically saves the data file when the user exits FUNCTION INPUT.
OFF* Does not automatically save the data file on EXIT. User must respond to display
prompt:
Save Data File?