M3000 Portable Bar Code Reader User's Guide
9-2
Message Cause Solution
Transmit Error
Indicates that the transmit
communications aborted with an error.
Retry communications.
User Abort
A key was pressed on the M3000,
causing an abort.
Decrease baud rate.
Wedge Cable Is
Not Connected
The keyboard wedge cable is not
connected when trying to do a keyboard
wedge upload.
Check cables and check transmit setup
parameters.
Xmodem Error
Unable to connect using XMODEM
protocol.
Check cables and check transmit setup
parameters.
Bar Code Data Errors
Bar Code Is Too
Long For Input
Bar code has more characters than
allowed by maximum input size
specification.
Scan correct size bar codes or midify
input size in the program.
Bar Code Is Too
Short For Input
Bar code has fewer characters than
allowed by minimum input size
specification.
Scan correct size bar codes or midify
input size in the program.
Invalid Bar Code
Data For Input
Bar code data does not match the
current input's data specifications
Scan correct bar codes or modify input
data specifications in the program.
Invalid
Bar Code Type
Scanned bar code does not match
acceptable bar code types specified for
the current input.
Scan correct bar codes or modify bar code
types in the program.
Function Recall Errors
Recall Buffer
Is Empty
No information has been stored using
FUNC + STORE.
Enter data and save for
FUNC + RECALL
Recall Data Not
Valid For Input
RECALL data does not match the
current input's data specifications.
Modify recall data or change input data
specifications in the program.
Recall Data Too
Large For Input
Contents of RECALL buffer exceed
maximum input size specification.
Modify recall data or change input size in
the program.
Miscellaneous Errors
*END OF FILE*
No More Inputs
End of defined program inputs has
been reached.
None.
Battery Low
Press Any Key
Battery low detected. Replace 9V Alkaline battery.
Clock Error
No Response
Real Time Clock is not responding. Call for service.
External Ram
Error
M3000 has detected an external RAM
error.
Call for service.
FATAL FILE ERROR
M3000 has detected an un-recoverable
file error.
None
FILE ERROR
M3000 has detected a file error and will
attempt to repair file contents
None
Input Is Full
Cannot Insert
Maximum input size specification has
been reached, and will not allow
additional characters.
Press INS key to exit out of the insert
mode.