6Setup Procedures
6-21
Read Delay (0.0 - 9.9 SEC)
Valid only if Always Run is ON. This option sets the delay period between successive reads of
the same bar code. This allows the removal of the bar code from the scan field without multiple
reads. The read delay can be set for 0.0 (no delay) to 9.9 seconds, in tenth of a second increments.
The default setting is 1.0 second.
Other Options
Bar Code ID
ON Transmit the bar code identifier character at the beginning of the bar code data. There is
one space between the ID character and the bar code data. The following characters
identify Bar Code ID's:
OFF * Do not transmit Bar Code ID
Dupli Reads (Duplicate Reads)
ON * Enable reading the same bar code multiple times.
OFF Disable reading the same bar code twice in a row.
F1-F10 Keys
ON* Enable reading of FUNCTION KEYS in place of ASCII characters.
OFF Disable reading of FUNCTION KEYS.
Special Keys
ON* Enable reading of SPECIAL KEYS in place of ASCII characters.
OFF Disable reading of SPECIAL KEYS.
NOTE: See Appendix L Non-ASCII Special Character Definitions for FUNCTION KEY and
SPECIAL CHARACTER definitions.
Transmit Setup
The Transmit Setup allows you to specify the type of data the M3000 sends, the mode that
transmits the data, and presets features such as dialing type, phone number, and serial
communications parameters.
NOTE: Transmit Setup is used for FUNC XMIT only, and is not used for Non Portable Modes.
Data
Data options are MENU and SEND ALL. The default is MENU.
MENU* Enables the "Upload Selection" menu in the Transmit Mode. This option allows you
to select specific data files for transmission.
SEND ALL Bypasses the "Upload Selection" menu, and transmits ALL data files stored in the
M3000.
A CODE 39 G CODABAR
B UPC-A H CODE 128
C UPC-E I CODE 93
D EAN-13 J MSI
E EAN-8 K CODE 11
F INTERLEAVED 2 of 5